07/02/2015

The Maryville Train Derailment: Emergency Response and Medical Management

Exposure: Hydrocyanic Acid
7/2/2015 12:00:00 AM..ToString("MM/dd/yyyy")
The Maryville Train Derailment: Emergency Response and Medical Management
Exposure: Hydrogen Sulfide

Overview

On July 2, 2015, a CSX freight train carrying hazardous materials derailed in Maryville, Tennessee. The derailment resulted in the release and combustion of acrylonitrile, a toxic and flammable chemical, leading to the evacuation of over 5,000 residents, injuries to nearly 200 individuals, and widespread environmental concerns. This case study examines the medical management and safety considerations associated with the incident.

Maryville Overview Img
Figure 1. CSX train car on fire in Maryville, TN (credit: AP)

Background

A CSX train was traveling from Cincinnati, Ohio to Waycross, Georgia when a wheel bearing failure caused a tanker car to derail and catch fire in Maryville, Tennessee. The derailed car contained approximately 24,710 gallons of acrylonitrile, which leaked and ignited, releasing toxic combustion by products. When first responders consulted with the federal Interagency Modeling and Atmospheric Center (IMAAC) for airborne plume modeling, IMAAC experts recognized that burning acrylonitrile decomposes into hydrocyanic acid (also known as hydrogen cyanide or prussic acid). This information changed responders’ initial health and safety concerns and resulted in an emergency middle-of-the-night evacuation of approximately 5,000 people living and working within two miles of the fire. The fire burned for close to 19 hours, prompting emergency responses from multiple local, state, and federal agencies.


Chemical Description

Hydrocyanic acid is a lighter-than-air, colorless or pale blue, highly volatile, and extremely flammable and poisonous liquid or gas. Exposure can occur through inhalation, ingestion, or dermal contact. It is a cellular asphyxiant, preventing cellular oxygen utilization and leading to rapid onset of symptoms and potentially death. The CDC notes that hydrocyanic acid vapors are dangerous even below the odor threshold and can induce olfactory fatigue, meaning odors may not offer sufficient warning of exposure.


Medical Management

Signs and Symptoms of Hydrocyanic Acid Exposure

Exposure to hydrocyanic acid can result in the following symptoms:

  • Central nervous system depression
  • Cardiovascular collapse
  • Respiratory distress, including shortness of breath and chest tightness
  • Eye and skin irritation
  • Headaches
  • Nausea
  • Dizziness
  • Cyanide-like poisoning effects

Recommended Medical Treatment for Hydrocyanic Acid Exposure

According to CDC Medical Management Guidelines, recommended treatment includes:

  • Immediate removal from exposure source
  • Administration of high-flow oxygen
  • Administration of hydroxocobalamin or sodium thiosulfate
  • Rapid decontamination with water and soap
  • Supportive care, including airway management and intravenous fluids
  • Continuous cardiac and respiratory monitoring
  • Eye irrigation for ocular exposure
  • Not inducing emesis

Health Effects Observed

Ten first responders and 39 residents were treated at Blount Memorial Hospital for symptoms consistent with hydrocyanic acid exposure, including respiratory distress and neurological effects. A total of 25 patients were admitted for care and observation. The first responder exposures highlight the need for using respiratory protection when available.

Medical Treatment Received by Victims

Victims received symptomatic treatment including oxygen therapy, administration of hydroxocobalamin, and intravenous fluids. Decontamination procedures included removal of contaminated clothing and thorough skin and eye irrigation. Patients were monitored for delayed neurological and cardiovascular effects.


Considerations for First Responders

Decontamination Procedures

Hydrocyanic acid (or any cyanide-containing solution) can cause secondary contamination through either contact or off-gassing. Responders should initiate rapid decontamination by removing victims from the exposure zone, removing contaminated clothing, and irrigating exposed skin and eyes with copious amounts of water.

Responder Safety and PPE

Responders must wear appropriate PPE, including Level A or B protection and self-contained breathing apparatus (SCBA). Resuscitation must be accomplished using a barrier such as a bag-valve-mask device. Cyanide-specific gas detectors should be used to monitor air concentrations. Any vomitus should be treated as potentially toxic.


Considerations for Hospital Personnel

Decontamination Procedures

Healthcare providers should minimize time in proximity to patients who have been exposed to liquids (not gas) and should wear appropriate PPE when treating patients exposed to hydrocyanic acid, including butyl rubber gloves and gowns, eye protection, and respiratory protection. Staff should be trained to recognize symptoms of hydrocyanic acid exposure and in the use of decontamination procedures and PPE to prevent secondary exposure.

Provider Safety and PPE

Hydrocyanic acid (or any cyanide-containing solution) can cause secondary contamination through either contact or off-gassing. Accordingly, hospital personnel must ensure secondary contamination is minimized by isolating exposed individuals upon arrival. Patients should undergo decontamination prior to entering the emergency department, including removal of contaminated clothing and thorough washing of skin and eyes. Dedicated decontamination areas should be used to prevent exposure to hospital personnel and other patients.


Lessons Learned

The incident highlighted the need for rapid and accurate hazardous material identification and hazard communication. One of the key lessons learned was that chemicals on fire can decompose, so emergency actions may need to be predicated on this information rather than the initial scene size-up. IMAAC provided guidance for a middle-of-the-night emergency evacuation which was critical in minimizing exposure of people in the area. So, another lesson learned was the importance of contacting IMAAC when a large-scale hazardous materials incident occurs.


Discussion Questions for Emergency Planning

  • Based on the types of facilities and transportation networks in this area, what PPE and training are needed for first responders and hospital personnel?
  • How can facilities improve hazard identification for first responders?
  • How can emergency alert systems be improved to provide timely warnings to both workers and nearby communities?
  • What role should local hospitals play in chemical incident preparedness?
  • How can hospitals better prepare for mass casualty incidents involving chemical exposures?
  • What role should local public health agencies play in coordinating shelter-in-place orders and public communication?